WB-PDU-10-6: | |
---|---|
WB-PDU-10-9: | |
WB-PDU-10-12: | |
Availability: | |
Quantity: | |
WB-PDU-10
Webitelecomms
8517799000
1U horizontal or vertical mounting Swiss series metered Power Strip PDU
Why PDU is required ?
PDU is a device used for power distribution. It is a structure with multiple outlets. Required when handling network equipment and data center racks.
According to its functional characteristics, PDU can be used for different areas.
Basic features
0U , 1U , 1.5U international 19" standard mount PDU socket, with leak-current protector
Aluminum-alloy shell,made from block burn PC,Guage:3G 1.5mm²+Common plug
According to customer request, we could add AC or DC display
Color: Black or silver , customized color is available
Defaulted build-in ON/OFF switch
Children safty protect.
Braker protection, and fused.
Usual Webitelecomms PDU optional function
Functional list
Protection | On/off switch (defaulted) | Yes |
3-lights protection ( Surge , earth , power ) | Optional | |
Power indictor | Optional | |
Surge protection | Optional | |
Fuse | Optional | |
Current Meter | Optional | |
Circuit breaker | Optional 1P, 2P, 3P | |
Locking | N/A | |
Overload protector | Optional | |
NEON ON/OFF Light | Optional | |
Cables | PVC | Default |
RUBBER | Optional | |
LSZH | Optional | |
Shell | Alu-alloy | Default |
Plastic | Optional | |
SPCC | Optional | |
Mounting | 1U mounting ears | Default |
Revolving ears | Optional | |
Hook | Optional | |
Desktop | Optional |
Data spec
Socket Type | SEV 1011 Swiss Type Socket |
Input Lead | 3G x 1.5mm² X 2.0M |
Input Plug | SANS 164 Swiss Type Plug |
Rated Voltage | 250V, 50/60Hz |
Rated Current | 10A |
Max. Power | 2550W |
Input Cable Entry | Left side default , optional right or rear side |
Housing Case | Aluminum or Plastic , SPCC for customized case |
Product Width* Depth | 44.45 x 44.45 mm ( 1U ) |
Optional Fittings | 2pcs φ6x16mm cross bolt, 2pcs M6 float nut, User Manual |
Package | 1PC/Polybag + Cardboard box |
Certificates | CE , ROHS |
=Sample view
Drawing
FAQ:
1) If the PDU used as residential electrical device?
---Yes, the PDU can be treated as home used power socket.
2) what if I want both C13 , C19 onto same PDU
--- yes, it's available
3) Is the PDU comes with screws and nuts for installation ?
--- usually excluded ; sure it's ok to add upon demands.
4) What is your MOQ?
--- usually 100 pcs as our accessories products MOQ , different items will be different. We have indicated the MOQ for each item
in the price list.
5) How we trust Webitelecomms
---As Europe market, we have CE RoHS and other international safety standard for our products.
---As other market,international safety standard certificate also could be provided.
---2 years standard WARRANTY for mostly Webit products
6) How to customize the PDU
--- customized design is available, please contact sales for more bespoke design
1U horizontal or vertical mounting Swiss series metered Power Strip PDU
Why PDU is required ?
PDU is a device used for power distribution. It is a structure with multiple outlets. Required when handling network equipment and data center racks.
According to its functional characteristics, PDU can be used for different areas.
Basic features
0U , 1U , 1.5U international 19" standard mount PDU socket, with leak-current protector
Aluminum-alloy shell,made from block burn PC,Guage:3G 1.5mm²+Common plug
According to customer request, we could add AC or DC display
Color: Black or silver , customized color is available
Defaulted build-in ON/OFF switch
Children safty protect.
Braker protection, and fused.
Usual Webitelecomms PDU optional function
Functional list
Protection | On/off switch (defaulted) | Yes |
3-lights protection ( Surge , earth , power ) | Optional | |
Power indictor | Optional | |
Surge protection | Optional | |
Fuse | Optional | |
Current Meter | Optional | |
Circuit breaker | Optional 1P, 2P, 3P | |
Locking | N/A | |
Overload protector | Optional | |
NEON ON/OFF Light | Optional | |
Cables | PVC | Default |
RUBBER | Optional | |
LSZH | Optional | |
Shell | Alu-alloy | Default |
Plastic | Optional | |
SPCC | Optional | |
Mounting | 1U mounting ears | Default |
Revolving ears | Optional | |
Hook | Optional | |
Desktop | Optional |
Data spec
Socket Type | SEV 1011 Swiss Type Socket |
Input Lead | 3G x 1.5mm² X 2.0M |
Input Plug | SANS 164 Swiss Type Plug |
Rated Voltage | 250V, 50/60Hz |
Rated Current | 10A |
Max. Power | 2550W |
Input Cable Entry | Left side default , optional right or rear side |
Housing Case | Aluminum or Plastic , SPCC for customized case |
Product Width* Depth | 44.45 x 44.45 mm ( 1U ) |
Optional Fittings | 2pcs φ6x16mm cross bolt, 2pcs M6 float nut, User Manual |
Package | 1PC/Polybag + Cardboard box |
Certificates | CE , ROHS |
=Sample view
Drawing
FAQ:
1) If the PDU used as residential electrical device?
---Yes, the PDU can be treated as home used power socket.
2) what if I want both C13 , C19 onto same PDU
--- yes, it's available
3) Is the PDU comes with screws and nuts for installation ?
--- usually excluded ; sure it's ok to add upon demands.
4) What is your MOQ?
--- usually 100 pcs as our accessories products MOQ , different items will be different. We have indicated the MOQ for each item
in the price list.
5) How we trust Webitelecomms
---As Europe market, we have CE RoHS and other international safety standard for our products.
---As other market,international safety standard certificate also could be provided.
---2 years standard WARRANTY for mostly Webit products
6) How to customize the PDU
--- customized design is available, please contact sales for more bespoke design