Network Cabinet Used AC Fan For Environment Cooling
Cooling fan is used to make a outgoing channel for exhaust airflow, make the cabinet inner environment to be cooling and suitable for network equipment ; WebiTelecomms generally use 2 sorts of fan dimensions for cabinets :
120*120*25 for wall cabinet
120*120*38 for floor cabinet
Varies of voltage model available : 110V , 220V , USB powered (5V,19V)
Both ball-bearing / sleeve available.
Features
1. Packaging Detail: white/color box, blister package
2. Normal Operating Temperature: 25°C-45°C
3. Life Expectancy: Dual Ball Bearing: 50000 hours
Sleeve Bearing and or oiliness : 20000-25000 hours
4. Standard: Fully CE, ROHS Approved
Parameter
Model | Type | Volt | Fre | Current | Consumption | Speed | Air-flow | Air pressure | Noise | |
Sleeve | Ball | VA | Hz | Amps | Watts | RPM | CFM | inch-H2O | dBA | |
12038-110S | √ | 115 | 50/60 | 0.21/0.18 | 20/18 | 2550/2700 | 80/98 | 0.25/0.3 | 43/48 | |
12038-110B | √ | 20/18 | 2600/2800 | 82/100 | 0.26/0.32 | 34/39 | ||||
12038-220S | √ | 220-240 | 0.12/0.11 | 20/19 | 2550/1700 | 80/98 | 0.25/0.3 | 43/48 | ||
12038-220B | √ | 20/19 | 2600/2750 | 82/100 | 0.26/0.32 | 34/39 |
Using tips
1. Do not touch the blades and the power cord wrapped around the fan or pull the power cord, otherwise the axis and power cord will be damaged;
2. Please avoid dust, water droplets, and insects from entering, which will affect the life and produce defective products;
3. Do not use in flammable gas and any harmful environment;
4. Please use it within six months. Long-term storage will affect the performance of the fan due to the storage environment;
5. When the fan is running, please do not try to lock the fan for a very long time, this will cause high heat and burn the fan due to continuous stop and no rotation;
6. When installing the fan, please pay special attention to the noise caused by resonance or vibration;
7. During transportation or operation, if the fan falls from a height of 60cm, it will have some impact on the balance of the blades, especially the ball bearings to avoid falling;
8. The screw torque of the lock shell shall not exceed 4Kgf; please do not use a screwdriver, iron rod, etc. to block the fan, which will damage the fan;
9. Please note that the fan will hurt your fingers when it runs at high speed.
=Shipment & Delivery =
Shipment | Note |
Express | Door to door, very convenient, don't need to clearance or pick-up |
By air | Airport to airport, you need to do the customs clearance and pick up the goods at your local airport |
By sea | Port to port and you need to do the customs clearance and pick-up the goods at your local port |
Webitelecomms take great commitments to photograph products indeed without any cheating and plagiarism.
Network Cabinet Used AC Fan For Environment Cooling
Cooling fan is used to make a outgoing channel for exhaust airflow, make the cabinet inner environment to be cooling and suitable for network equipment ; WebiTelecomms generally use 2 sorts of fan dimensions for cabinets :
120*120*25 for wall cabinet
120*120*38 for floor cabinet
Varies of voltage model available : 110V , 220V , USB powered (5V,19V)
Both ball-bearing / sleeve available.
Features
1. Packaging Detail: white/color box, blister package
2. Normal Operating Temperature: 25°C-45°C
3. Life Expectancy: Dual Ball Bearing: 50000 hours
Sleeve Bearing and or oiliness : 20000-25000 hours
4. Standard: Fully CE, ROHS Approved
Parameter
Model | Type | Volt | Fre | Current | Consumption | Speed | Air-flow | Air pressure | Noise | |
Sleeve | Ball | VA | Hz | Amps | Watts | RPM | CFM | inch-H2O | dBA | |
12038-110S | √ | 115 | 50/60 | 0.21/0.18 | 20/18 | 2550/2700 | 80/98 | 0.25/0.3 | 43/48 | |
12038-110B | √ | 20/18 | 2600/2800 | 82/100 | 0.26/0.32 | 34/39 | ||||
12038-220S | √ | 220-240 | 0.12/0.11 | 20/19 | 2550/1700 | 80/98 | 0.25/0.3 | 43/48 | ||
12038-220B | √ | 20/19 | 2600/2750 | 82/100 | 0.26/0.32 | 34/39 |
Using tips
1. Do not touch the blades and the power cord wrapped around the fan or pull the power cord, otherwise the axis and power cord will be damaged;
2. Please avoid dust, water droplets, and insects from entering, which will affect the life and produce defective products;
3. Do not use in flammable gas and any harmful environment;
4. Please use it within six months. Long-term storage will affect the performance of the fan due to the storage environment;
5. When the fan is running, please do not try to lock the fan for a very long time, this will cause high heat and burn the fan due to continuous stop and no rotation;
6. When installing the fan, please pay special attention to the noise caused by resonance or vibration;
7. During transportation or operation, if the fan falls from a height of 60cm, it will have some impact on the balance of the blades, especially the ball bearings to avoid falling;
8. The screw torque of the lock shell shall not exceed 4Kgf; please do not use a screwdriver, iron rod, etc. to block the fan, which will damage the fan;
9. Please note that the fan will hurt your fingers when it runs at high speed.
=Shipment & Delivery =
Shipment | Note |
Express | Door to door, very convenient, don't need to clearance or pick-up |
By air | Airport to airport, you need to do the customs clearance and pick up the goods at your local airport |
By sea | Port to port and you need to do the customs clearance and pick-up the goods at your local port |
Webitelecomms take great commitments to photograph products indeed without any cheating and plagiarism.