Model: | WB-STS-800 |
Place of Origin: | Zhejiang,China (Mainland) |
Brand Name: | WEBITELECOMMS |
Material: | SPCC |
Socket type: | IEC60320 C13 |
Input Plug: | IEC 60309 16Amp |
Power Lead Length: | 3 Metres |
Grounding: | External earth facility |
Size: | 19'' mounting |
Certificate: | CE ROHS |
Availability: | |
---|---|
Quantity: | |
WB-STS-800
Webitelecomms
19 inch RACK-MOUNT 12-way C13 STS switch PDU
The dual power automatic switching PDU redundant power supply is called ATS or STS.
ATS is mainly used in emergency power supply systems to automatically switch the load circuit from one power source to another (backup).
It makes sure continuous and reliable operation of important loads.
Therefore, STS is often applied in important power plants, and its product reliability is particularly important. Once the conversion fails, it will cause one of the following two hazards: short circuit between power sources or power outage of important loads (or even brief shutdown)
Features:
IEC60320 C13 outlets
IEC 60309 (16 Amp) *2 pcs
LCD indicated unit power
19 inch rack mounting
3 Metres *2.5mm² PVC * 2 pcs lead
High quality,cold rolled steel housing
Up to 12 sockets per unit
250 volt AC, 50/60Hz Rating
External earth facility
CE compliant, ROHS complaint
Specification:
LCD display: real time current; A source / B source voltage
Switch Time: A source cut off - 7ms is needed, A source arc extinguished - 6 to 10 ms, B source start to work - 7ms is needed , Total no more than 25 ms
Using the ''Relay'' to switch from source A To source B
RS232 port: Mintoring via Computer
Product Overview:
The STS power distribution units are designed for installation and use within 19" networking cabinets and enclosures.
It has dual 16A input power cords supplying power to the connected load.
The button "preference" is to chose "source A" or "source B" work preferentially.
If the primary power source becomes unavailable, the rack STS will seamlessly source power from the secondary source without interrupting critical loads.
19 inch RACK-MOUNT 12-way C13 STS switch PDU
The dual power automatic switching PDU redundant power supply is called ATS or STS.
ATS is mainly used in emergency power supply systems to automatically switch the load circuit from one power source to another (backup).
It makes sure continuous and reliable operation of important loads.
Therefore, STS is often applied in important power plants, and its product reliability is particularly important. Once the conversion fails, it will cause one of the following two hazards: short circuit between power sources or power outage of important loads (or even brief shutdown)
Features:
IEC60320 C13 outlets
IEC 60309 (16 Amp) *2 pcs
LCD indicated unit power
19 inch rack mounting
3 Metres *2.5mm² PVC * 2 pcs lead
High quality,cold rolled steel housing
Up to 12 sockets per unit
250 volt AC, 50/60Hz Rating
External earth facility
CE compliant, ROHS complaint
Specification:
LCD display: real time current; A source / B source voltage
Switch Time: A source cut off - 7ms is needed, A source arc extinguished - 6 to 10 ms, B source start to work - 7ms is needed , Total no more than 25 ms
Using the ''Relay'' to switch from source A To source B
RS232 port: Mintoring via Computer
Product Overview:
The STS power distribution units are designed for installation and use within 19" networking cabinets and enclosures.
It has dual 16A input power cords supplying power to the connected load.
The button "preference" is to chose "source A" or "source B" work preferentially.
If the primary power source becomes unavailable, the rack STS will seamlessly source power from the secondary source without interrupting critical loads.